Browse all practice questions for the FDNY Respiratory Medical Officer (RMO) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

FDNY Respiratory Medical Officer (RMO) Practice Exam 2026 – Comprehensive All-in-One Resource for Exam Success! course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is the primary purpose of using a filter dryer in a refrigeration system?
  • The phenomenon of violent vibration in a steam turbine at critical speed can lead to what problem?
  • What is the responsibility of a B29 CoF Holder?
  • What is the most likely cause of cavitation in a chilled water pump?
  • The rupture disc for a low-pressure centrifugal refrigeration machine is typically located on which component?
  • Why is it important to control the speed of a steam turbine during operation?
  • What is typically the first step after recovering all liquid refrigerant from a system intended for overhaul?
  • What is the primary method of achieving capacity control in a centrifugal compressor?
  • What are pre hot work procedures performed prior to hot works?
  • Which of the following would be a sign of a malfunction in a refrigeration system?
  • The vibration of a steam turbine approaching critical speed indicates what kind of risk?
  • What could be the cause of a knocking sound in a reciprocating compressor if worn parts are ruled out?
  • How is the electrical power used to operate a solenoid valve measured?
  • Which factor can be adjusted to improve the cooling efficiency of a condenser?
  • Which type of refrigerant system is least prone to leaking refrigerant?
  • What indicates the need to check the condenser water pump in a refrigeration system?
  • How does the presence of moisture affect the performance of a steam turbine?
  • What is the primary function of the turbine auxiliary oil pump?
  • When is a centrifugal water pump considered fully primed?
  • What term describes the ratio of actual water vapor pressure to the saturated pressure at a given temperature?
  • How long should a fire watch be maintained if a standpipe system is out of service for two days?
  • What material is commonly used for modern compressor shaft seals?
  • How is capacity control of a reciprocating hermetic compressor typically achieved?
  • Centrifugal chillers are best characterized by which of the following features?
  • What is the approximate volume, in cubic inches, of a reciprocating compressor cylinder with a 10-inch bore and a 14-inch stroke?
  • What device is responsible for automatically controlling the speed of a steam turbine?
  • How does a cylinder unloader function in a refrigerant system?
  • What purpose does an equalizer line serve on a thermal expansion valve (TEV)?
  • What is the most likely cause of high discharge pressure and high normal subcooling in a refrigeration system controlled by a TEV?
  • What does the packing gland of a centrifugal pump indicate when it has a drip?
  • Which of the following best describes the function of a check valve in a pump system?
  • What is a potential consequence of an improperly set thermal expansion valve?
  • What will occur in the evaporator if the external equalizer line is disconnected?
  • What is the primary purpose of using a low side float valve in a refrigeration system?
  • What is the most common metering device in reciprocating commercial refrigeration systems with a capacity of under three tons?
  • If R134 accidentally touches a refrigeration engineer's skin, what first aid should be applied?
  • Why should moisture in the inlet of a steam turbine be kept as low as possible?
  • What is the primary purpose of using a digital thermometer in a refrigeration system?
  • What is the ASHRAE classification for ammonia as a refrigerant?
  • During a routine check, what is the most likely cause of a frosted suction line and compressor?
  • The oil pressure gauge reading in relation to the suction pressure of a compressor should be closer to:
  • While performing hot works near a sprinkler head, what can be done to prevent the fire alarm from activating?
  • What can cause a decrease in removal rates when recovering vapor refrigerant?
  • What type of vapor is present at the end of a properly operating evaporator with an expansion valve?
  • Where are the suction and discharge valves mounted on a reciprocating compressor?
  • What is the primary function of the equipment that detects refrigerant leaks?
  • A FDNY permit is required for which of the following activities?
  • In a single-phase 208 VAC circuit, how many hot wires are typically present?
  • What is the function of the vacuum breaker in a steam turbine?
  • What is a compressor safety head?
  • For which reason might impurities be removed from a refrigerant system?
  • What is the result of using an oversized compressor in a refrigeration system?
  • In a condenser, the heat to be removed from the refrigerant is equal to the heat gained in which component?
  • A refrigerant leak in the evaporator shell of a system using R123 will likely result in what condition?
  • What should be done when all liquid has been recovered from a refrigeration system prior to an overhaul?
  • For how long must a fire alarm log book be maintained?
  • What is the purpose of a water regulating valve in a condenser system?
  • What is one common indication of a refrigerant leak in a refrigeration system?
  • In a refrigeration cycle, where is heat absorbed from the environment?
  • An advantage of using glycol instead of salt brine as an intermediate cooling medium is:
  • Which of the following compressors is classified as not being a positive displacement type?
  • What is the volume of a box that measures 12 inches on each side?
  • In a multizone standpipe system, how is water supplied to each zone?
  • Why are copper and aluminum commonly used for condenser tubes in refrigeration systems?
  • How is the viscosity of lubrication oil described?
  • When one centrifugal pump in parallel is throttled back, what is the result?
  • A chilled water system with an air-cooled condensing unit on a roof during cold weather has what type of protection?
  • Which property is considered desirable in a refrigerant?
  • What type of liquid refrigerant has passed through a metering device?
  • What is the role of oil in a refrigeration machine?
  • What is one possible consequence of running a refrigeration unit with low refrigerant levels?
  • What is the consequence of an improperly calibrated pressure gauge?
  • What is a critical parameter for assessing cooling tower performance?
  • In a refrigerant system, what does a rising suction gauge reading indicate?
  • What is the correct method for calibrating a thermometer?
  • What two characteristics is the ASHRAE refrigerant safety group classification system based upon?
  • Which component's malfunction could lead to compressor overheating?
  • What color must cross connections and standpipe risers be painted?
  • According to code, where is emergency power not typically required?
  • What is the height of the water column in feet when the pressure gauge at the pump's inlet shows 140 PSIG?
  • Which component is crucial for ensuring efficient refrigerant expansion in a refrigeration system?
  • What does short cycling in a centrifugal compressor using a low side float valve typically indicate?
  • A circuit breaker serves a function similar to which of the following?
  • What is a potential consequence of refrigerant leaking from an evaporator?
  • What effect does a leak in the evaporator shell of a chill water system using R134a have?
  • For which type of refrigerant is FDNY approval required?
  • Which component is not used to vary the flow of refrigerant in a refrigeration system?
  • What is a common indication of refrigerant contamination in a compressor?
  • When entering Phase 11 fireman's service, who has control of the elevator?
  • What is a major advantage of a shell and coil condenser?
  • Why is the selection of the right refrigerant critical in HVAC systems?
  • Which condition would likely indicate a need for superheating in a refrigeration system?
  • What is the correct procedure to put an additional pump online in a refrigeration system?
  • What is the maximum amount of extra refrigerant that can be stored in a machine room?
  • Which of the following best describes a standpipe hose outlet?
  • In refrigeration systems, what is primarily stored in the compressor?
  • Where do non-condensable gases, like air or nitrogen, typically accumulate in a refrigerant system?
  • After leak testing with R22 and nitrogen, what should be the next step?
  • Which type of valve is most effective for controlling pressure in a refrigeration system?
  • Refrigeration systems that require FDNY approval typically handle which refrigerant?
  • When would the most damage occur to a centrifugal pump with a leaking check valve?
  • What mechanism primarily removes heat in a cooling system?
  • What is one of the major benefits of properly functioning lubrication in equipment?
  • What instrument should an engineer use to check for shorts in the motor windings?
  • How much does 2.5 gallons of water weigh?
  • If a refrigerant chart indicates a temperature of 5 degrees Celsius, what is the equivalent temperature in Fahrenheit?
  • Which of the following components is essential in maintaining the operational stability of a steam turbine?
  • If the chilled water supply to a building is 55F, what should be your concern if it’s used for human comfort?
  • In a 2000 ton centrifugal refrigeration system, what is the first step if the panel indicates a water flow issue?
  • Where is the muffler typically located in a refrigeration system?
  • A faulty compressor valve can lead to which of the following issues?
  • What could be a consequence of a steam turbine operating at critical speed without regulation?
  • If resistance is cut in half, what happens to the power factor?
  • What is the correct order of components on the liquid line of a reciprocating system from the condenser to the TEV?
  • Why is a refrigerant gauge referred to as a compound gauge?
  • What effect does lowering the condensing pressure have in a refrigerant cycle?
  • What is the primary function of a governor valve in a steam turbine system?
  • What is the benefit of using fireproof decorations in buildings?
  • What issue can arise if the water supply to a pump's suction inlet is below its level?
  • What is the equivalent energy consumption for a 5 horsepower motor operating for 9 hours in kilowatt-hours?
  • What is typically responsible for regulating refrigerant flow in cooling systems?
  • What is a key advantage of forced draft cooling towers over natural draft cooling towers?
  • What is a possible consequence of failing to maintain water treatment in a refrigerant system?
  • What happens to the efficiency of a centrifugal compressor when the condensing pressure is lowered?
  • What is the most likely cause of cavitation in a condenser water pump?
  • What aspect of turbine performance is most directly affected by fluctuations in speed?
  • What should be the minimum pressure graduation rate for a gauge on the high side of a system?
  • How often should a sprinkler system that is offline be inspected until it is restored to service?
  • When refrigerant, water, and oil are observed together, in what order do they settle in a container?
  • Why is it important to check oil levels in a centrifugal chiller?
  • Which feature of fusible plugs is critical to their operation in a condenser system?
  • What happens to the oil collected in an oil separator?
  • In cooling systems, what is the primary purpose of refrigerant flow regulation?
  • If you are running a 2000-ton steam-driven turbine centrifugal refrigeration system and the panel indicates a water flow issue, what is the appropriate action to take?
  • Where should the bulb of the thermal expansion valve be attached during inspection?
  • What type of heat is removed from the refrigerant in a condenser?
  • In a semi-hermetic compressor, what is the primary function of the suction vapor?
  • What is an appropriate action when a refrigerant leak is suspected in a system?
  • Centrifugal pressure in a system is primarily determined by what factor?
  • What is usually the first indication of a problem when water treatment of the condenser water is not maintained?
  • If you are the only engineer on duty and a vice president asks you to shovel snow, what should you do?
  • What device is used to convert 110 volts to 24 volts in an electrically operated control system?
  • What is the benefit of installing an inline refrigerant cleaning system?
  • What method is used on an outside pipe to prevent it from freezing?
  • What could cause high condenser pressure in a system with clean condenser tubes?
  • At what pressure is a relief valve expected to start functioning?
  • What is the ratio of suction pressure to discharge pressure in a centrifugal compressor operating at 3 psig and 10 psi respectively?
  • What is usually the third wire in a single-phase 208 VAC circuit?
  • What could lead to a decrease in the efficiency of a reciprocating compressor?
  • If a reciprocating compressor has a suction pressure of 65 psig and a discharge pressure of 120 psig, what is the compression ratio?
  • Which equipment connects to the middle port on a gauge manifold?
  • What causes the atmospheric valve to open on a steam turbine?
  • To superheat a refrigerant, it must be heated in which section of the refrigerant line?
  • What classification do electric devices used for built-in defrosting of refrigeration machines fall under?
  • Which refrigerant is known for having the highest latent heat and refrigerant effect in commercial and industrial applications?
  • What type of valve is used to manage high-pressure situations in HVAC systems?
  • What happens when there is a restriction in the refrigerant liquid line of a water chiller equipped with a reciprocating compressor?
  • What type of valve should be installed to isolate a dual pressure relief valve while keeping the system in service?
  • What performance aspect distinguishes shell and tube condensers from shell and coil condensers?
  • What likely causes oil foaming in the crankcase of an R-22 single acting compressor system?
  • Which of the following is NOT a feature of the governor valve?
  • A water pump is discharging against a head of 92 feet of water. What is the approximate pressure in psi?
  • Which component is typically not required to be serviced annually?
  • What causes the opening of the solenoid valve in a refrigeration system?
  • What do approved refrigerant containers ensure during storage?
  • What is the charge of a TEV sensing bulb similar to?
  • If a temperature chart indicates a Celsius temperature of 4 degrees, what is the equivalent in Fahrenheit?
  • A low viscosity number for lubrication oil indicates what about its flow characteristics?
  • When installing copper tubing refrigerant lines that require bends, what tool should be used to avoid collapsing the tubing?
  • In a refrigeration system, what effect does increased condenser pressure have?
  • What action should be taken if the condenser water pump fails during operation?
  • What action should an engineer take if most buildings are satisfied with chill water, except one?
  • What is the typical role of latent heat in a condenser?
  • What is the primary role of the Kingsbury thrust bearing in a steam turbine?
  • Who is permitted to leave the building refrigeration system when it is in operation?
  • Which of the following does not require flame resistant treatment?
  • What is the cooling medium for a cooling tower?
  • What is the consequence of insulation breakdown on a thermal bulb attached to a suction pipe?
  • Regardless of the ASHRAE refrigerant classification in use, what should the engineer be aware of in the event of a refrigerant escape?
  • At a dry bulb temperature of 75 degrees and a wet bulb temperature of 73 degrees, what is the likely relative humidity?
  • What is often used as the initial troubleshooting step in refrigeration systems?
  • What is the purpose of steam ejectors on the surface condenser of a system with a turbine?
  • An engineer observes a gauge that reads saturation pressure of a refrigerant. If chilled water is circulated as the cooling medium, what can this reading best estimate?
  • Which type of pump is typically shown in an insulated configuration in a refrigeration system?
  • In a steam turbine system, maintaining proper speed is crucial for what reason?
  • After recovering liquid refrigerant from a centrifugal chiller, what is the next step?
  • If the suction pressure of a reciprocating compressor rises rapidly after stopping, what is the most probable cause?
  • What is the primary purpose of installing a muffler in a reciprocating refrigerant machine?
  • What is the function of capacitors on refrigeration motors?
  • Which of the following represents a reason to troubleshoot a cooling system?
  • What is the purpose of a low side float valve in a refrigeration system?
  • What is the primary function of gland steam in a steam turbine?
  • Which statement accurately characterizes a centrifugal refrigerant machine?
  • What is the most likely cause of a starved evaporator?
  • Which ASHRAE refrigerant classification is FDNY most concerned with?
  • What is the typical feature of liquid level gauge glasses?
  • Where is the charging valve typically located on a refrigeration system?
  • What is the most widely used regulation book among operating engineers?
  • What is the primary use of a psychrometer by refrigeration engineers?
  • What is the function of the equipment that removes non-condensables from the condenser?
  • Which characteristic accurately describes a hermetic compressor?
  • What is the nature of R134 refrigerant as described by the Material Safety Data Sheet (MSDS)?
  • Where must the Material Safety Data Sheet (MSDS) be located?
  • What component in the refrigeration cycle is responsible for compressing the refrigerant?
  • Why is it important to use at least two compressors in a cascade system?
  • The vessel generally used in connection with refrigerant recovery is:
  • How many BTUs are removed in a 30 ton cooling system per hour?
  • What is the effect of not maintaining sufficient refrigerant levels in a system?
  • What is the primary requirement for fire alarm books?
  • Under what conditions is it permissible to chain an exit door?
  • What immediate action is recommended when the condenser water temperature is higher than desired?
  • Monitoring which parameter is essential for preventing turbine failure?
  • Which device is responsible for protecting the steam turbine from excessive speed?
  • Which ASHRAE refrigerant safety classification is considered the most flammable?
  • What kind of design does a centrifugal pump typically utilize?
  • Which information is typically absent from a Material Safety Data Sheet (MSDS)?
  • Which of the following can lead to system inefficiency in refrigeration systems?
  • What characteristic of the indirect refrigerant system contributes to its leak prevention?
  • What should the flash point of compressor lubricating oil be in relation to the compression temperature?
  • What is the most important reason to sub-cool refrigerant in the condenser?
  • Electrical current is commonly measured in what unit?
  • According to fire safety regulations, what must be ensured when storing refrigerant in containers?
  • Which device is used to measure the speed of a turbine?
  • A refrigeration engineer notices excessive cycling of the temperature control for a reciprocating compressor. What might be causing this condition?
  • Which ASHRAE refrigerant safety classification indicates no flammability and lower toxicity?
  • As an engineer, what action should you avoid when the discharge pressure of your condenser water pumps is significantly lower than normal?
  • What does a high reading on a condenser pressure gauge typically indicate?
  • What is an essential feature of condensers in a refrigeration system?
  • Which components are typically involved in a refrigerant pump system?
  • In the context of a centrifugal refrigeration system, what would you check if the system is not operating correctly?
  • Under normal conditions, how does refrigerant enter and leave the compressor?
  • In a multi-stage centrifugal compressor, each stage is:
  • If a valve handle is at a 45-degree angle, in what position is the valve?
  • What is the cooling medium for an evaporative condenser?
  • What happens when a thermal bulb's insulation fails in the refrigeration cycle?
  • Emergency power testing must be conducted how frequently?
  • After verifying the electrical circuit to the refrigeration compressor, what is the next component that should be checked if the compressor does not turn on?
  • What component helps to join different sections of piping in refrigeration systems?
  • What is a common reason for reduced effectiveness in a sprinkler system?
  • Which of the following is a method used to ensure proper refrigerant flow in a cooling system?
  • What does a wiring diagram typically depict?
  • What can be found marked on fusible plugs located on a condenser?
  • What is a common cause of increased high side pressure in a refrigeration system?
  • When faced with a refrigerant line that has collapsed at a bend, what practice is best to prevent this?
  • What is the purpose of wear rings in a centrifugal pump?
  • What is a superheated vapor?
  • What does a Thermal Expansion Valve (TEV) maintain constant?
  • What will happen if some unloaders in a multi-cylinder reciprocating compressor fail to operate when needed?
  • Which factor contributes to high efficiency in refrigeration systems?
  • If you notice unusual noise and hot operation of condenser pump #1, what should you do?
  • What is the purpose of adding chemical additives to cooling tower water?
  • What should be done first when starting up a centrifugal chiller's system?
  • What is the process of extracting and cleaning refrigerant for reuse without requirements called?
  • What is the most crucial requirement for an effective evaporator?
  • What occurs when a steam turbine reaches critical speed?
  • In a cold front scenario with a sudden temperature drop, how would the thermostat respond regarding the solenoid valve?
  • Why does the removal rate of refrigerant slow down when using a portable compressor recovery unit?
  • What is the primary function of a safety head on a compressor?
  • What is the main reason for using ribbed metal piping for electrical wires connected to the refrigeration system?
  • What is the role of a throttle valve in a steam turbine system?
  • What is the purpose of the oil charging port on a compressor?
  • What happens to moisture levels in the air when its temperature drops?
  • An automatic expansion valve primarily maintains which of the following?
  • What must a refrigeration system remove to convert water at 32°F to ice at the same temperature?
  • If 29.92" HG equals 14.7 Psia, what is the conversion of 26" HG to Psia?
  • What type of vapor does a compressor primarily discharge?
  • What equipment should manifold hoses be equipped with?
  • Which example represents an in-line refrigerant cleaning system for use with a centrifugal compressor containing R123 refrigerant?
  • The elimination of corrosion in a cooling medium system can be achieved by using:
  • When is a centrifugal water pump classified as a lift pump?
  • What is a common fault that might cause a motor to trip on overload?
  • What is a key advantage of a shell and tube condenser over a shell and coil condenser?
  • What is essential to monitor in a centrifugal pump to ensure proper operation?
  • How long typically does it take for a steam turbine to warm up?
  • Which refrigerant state is typically present after passing through a metering device?
  • In an indirect refrigeration system, which of the following is NOT used as a cooling medium for building spaces?
  • If a condenser pump is not running and the pressure gauge shows 55 psi, what is the approximate floor level of the cooling tower?
  • What is the primary goal of maintaining proper condenser water treatment?
  • If 10 BTUs are transferred to 10 pounds of water, what will be the closest increase in water temperature?
  • What might cause high suction superheat in a refrigeration system?
  • What method can help avoid problems with water and moisture in a refrigerant system?
  • What is the minimum frequency for logging readings by an engineer?
  • How many gallons of water can be expected from draining a 75-foot long pipe with a diameter of 12 inches?
  • If a restriction develops in the refrigerant flow to a jet ejector in an oil-raising system, what may occur?
  • What is the first step to start a centrifugal chiller?
  • Which type of sprinkler system requires regular inspection?
  • What type of refrigerant is found inside the machine's gauges?
  • What is the state of refrigerant as it enters the compressor in a reciprocating machine?
  • In the absence of chemical treatment, how often should a cooling tower be drained and replaced with fresh water?
  • Which component is essential for maintaining the proper operation of a refrigeration system's pressure?
  • What is a potential risk of operating a compressor with low oil levels?
  • Where can one find information about the physical and chemical properties of hazardous materials?
  • Which of the following is considered an essential maintenance item for chillers?
  • If a motor winding is touching the inside of the motor housing, what could be a potential consequence?
  • Which feature is most important for a fire alarm system to function properly?
  • The primary use of a jet ejector in a refrigeration system is to:
  • How many gallons of water are in a pipe that is 8 feet in diameter and 10 feet long?
  • When charging refrigerant on the low side of a reciprocating machine, what is the correct position of the manifold gauge?
  • What type of emergency response plan is vital for buildings with automatic sprinkler systems?
  • A standpipe certificate should be available for which parties?
  • What happens if the air louvers in an induced draft cooling tower become clogged?
  • When is a chemical fire extinguisher system needed?
  • Which safety measure is crucial when a turbine approaches critical speed?
  • What is the primary function of a high-side float valve in a refrigeration system?
  • What determines the amount of refrigerant that flows through the orifices of an economizer?
  • Why is a pressure relief valve preferred over a fusible plug in refrigeration systems?
  • When does the exchange of BTUs become greatest in a cooling system?
  • How is the water level controlled in the surface condenser hot well of a steam turbine?
  • In a refrigeration system, what might cause a significant drop in compressor discharge temperature alongside high suction line pressure?
  • What is the lowest temperature that a cooling tower can reach?
  • What maintenance strategy can prevent a steam turbine from reaching critical speed?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy